- Home
-
All Categories
- Kitchen & Dining
- Sports & Outdoors
- Automotive
- Clothing, Shoes & Jewelry
- Toys & Games
- Electronics
- Home & Kitchen
- Industrial & Scientific
- Patio, Lawn & Garden
- Computers & Accessories
- Tools & Home Improvement
- Sports Collectibles
- Office Products
- Arts, Crafts & Sewing
- Musical Instruments
- Baby
- Cell Phones & Accessories
- Camera & Photo Products
- Pet Supplies
- Health & Household
- Video Games
- Grocery & Gourmet Food
- Appliances
- Beauty & Personal Care
- Payment
- About Us
- FAQ
- Privacy Notice
- Shipping & Returns
- Contact Us
Your cart is empty.
Your cart is empty.- Home /
- Industrial & Scientific
- Filtration
- Occupational Health & Safety Products
- Fasteners
- Packaging & Shipping Supplies
- Industrial Hardware
- Industrial Electrical
- Additive Manufacturing Products
- Power Transmission Products
- Raw Materials
- Hydraulics, Pneumatics & Plumbing
- Food Service Equipment & Supplies
- Science Education
- Lab & Scientific Products
- Adhesives, Sealants & Lubricants
- Material Handling Products
- Cutting Tools
- Test, Measure & Inspect
- Janitorial & Sanitation Supplies
- Commercial Door Products
- Robotics
- Retail Store Fixtures & Equipment
- Abrasive & Finishing Products
- Digital Signage
- Professional Medical Supplies
- Professional Dental Supplies
- Power & Hand Tools
/
- Test, Measure & Inspect
- Electrical Testing
- Dimensional Measurement
- Substance Analysis Instrumentation
- Calibration
- Pressure & Vacuum
- Surface & Hardness Testing
- Scales & Balances
- Temperature & Humidity
- Motion, Speed & Force
- Recorders & Data Acquisition
- Light Measurement
- Sound & Noise Meters
- Inspection & Analysis
- Airflow & Air Quality
- Network & Cable Testers
/
- Electrical Testing /
- Power Meters
Product Description

Features
- Power quality analyzer for single-phase or balanced three-phase system.
- Voltage and Current are the True RMS value.
- ACV input impedance is 10 Mega ohms.
- True Power ( KW, MW, GW ) measurement.
- Apparent Power ( KVA, MVA, GVA ) measurement.
- Reactive Power ( KVAR, MVAR, GVAR) measurement.
- Power Factory ( PF ), Phase Angle (Φ ) measurement.
- Energy ( KWh, KVAh, KVARh, PFh ) measurement.
- Voltage measurement range: 10 to 600 ACV.
- Current measurement range: 5 to 2000 ACA.
- Graphic Phasor Diagram.
- Voltage and Current harmonic analysis ( 1-50th order ).
- Voltage and Current Total Harmonic Distortion analysis ( THD ) measurement.
- Voltage and Current waveforms show.
- Peak-to-Peak voltage and current measurement.
- Capture Transient events ( including Dip, Swell and Outage ) with programmable threshold ( % ).
- Thermocouple Temp. sensor:Type K ( -100.0°C to 199.9°C/200°C to 1300°C),°C/°F.
- Programmable PT ratio ( 1 to 1000 ).
- Safety Standard : IEC 1010, CAT IV 600V.
- Built-in clock and Calendar, real time data record with SD memory card , sampling time set from 2 to 7200 seconds. Just slot in the SD card into the computer, it can down load the all the measured value with the time information ( year, month, data, hour, minute, second ) to the Excel directly, then user can make the further data analysis by themselves.
- Allow save the LCD screen picture to the photo BMP file, it is the useful tool for the user to make the further analysis.
- Micro SD CARD 32 GB maximum supported capacity.
- Powered by AA (UM-3) DC1.5V X 2 batteries ( Alkaline type ) or DC 9V adapter ( linear 110V/220V ).
- Computer data output, can cooperate with optional USB Cable/USB-01, RS232 cable/UPCB-02 and Data Acquisition software, SW-U811-WIN.
- Optional type K probe: TP-11.
Technical Specifications
Circuit | Custom single-chip microprocessor LSI circuit |
Display | LCD Size: 3.2 X 2.4" (60 X 44.4 mm) / Dot Matrix backlit LCD (128 X 64 pixels) |
Measurements | ACV, ACA, KW / KVA/ KVAR/ PF, KWH/KVAH/KVARH/PFH, Power factor, Phase angle, Frequency, Harmonics display, Temperature |
Wire configurations | 1 Phase, 3 Phase |
Voltage ranges | 10 ACV to 600 ACV (Auto Range) |
Current ranges | 5 ACA to 2000 ACA (Auto Range) |
Safety standard | IEC1010 CAT IV 600 V |
ACV input impedance | 10 M ohms |
Clamp frequency response | 40 Hz to 1 KHz |
Tested clamp | 45 to 65 Hz |
Over-load protection | ACV: 720 ACV RMS | ACA: 2100 ACA with clamp probe |
Over-range | * LCD display show " OL ". | * The data save into the SD card will show " 9999 " or " 999 " (overleap the decimal point). |
Data Hold | Freezes displayed reading |
Datalogger | * Real time data logger, saved the data into SD memory card and down load the all the measured value with the time information ( year/month/data/ hour/minute/second ) down load to the Excel. | * Sampling time for data logger : 2 seconds to 7200 seconds, the during of setting step are 2 seconds | * Data error no. : ≦ 0.1% no. of total saved data typically. |
Data Recording | Micro SD memory card |
Sampling Time | Approx. 1 second |
Data Output USB/RS232 | * Computer interface | * Connect the optional USB cable USB-01 will get the USB plug. | * Connect the optional RS232 cable UPCB-02 will get the RS232 plug. |
Operating Temperature | 0 to 50°C ( 32 to 122°F ). |
Operating Humidity | 80% Relative Humidity max. |
Power Supply | *DC 1.5V, AA ( UM-3 ) Battery X 2 PCs (Alkaline or heavy-duty battery). | * AC to DC 9V power adapter ( LINEAR 110/220V ) |
Power Consumption | 60 mA DC |
Max. Conductor size | Clamp can accommodate up to 2.2" (57 mm) diameter |
Dimensions | 11.0 X 4.2 X 1.9" (280 X 106 X 47mm) | Clamp Jaw: 3.5" (90 mm) |
Accessories Included | Instruction manual....................... 1 PC 8 GB micro SD card...................... 1 PC Test Leads...................................1 set Alligator clips................................1 set AC to DC 9V adapter ( linear 110V/220V ).....................1 PC Carrying case...............................1 PC |
ELECTRICALSPECIFICATIONS (23±5°C)



$2,290.00 $2,290.00
$ 99 .00 $99.00
$25.75 $25.75
$ 11 .99 $11.99
$5.91 $5.91
$ 2 .99 $2.99
$1,115.00 $1,115.00
$ 99 .00 $99.00